Introduction 2
Performance / Specifications 3
Exploded View & Parts List 4
Pump Inspection And Handling 5
Pre-Installation 5
Installation 5-6
Location
Mounting
Piping
Electrical Connections 7-10
Start-up Procedure 11
Shaft Rotation
Valves
Priming
Starting
Final Inspection
Trouble Shooting 12
Table Of Contents
Introduction
This manual was prepared to assist the installer and/or operator in understanding the proper method of
installing, operating and maintaining the PC series centrifugal pump. We recommend that you thoroughly
understand the proper installation and start-up procedures, prior to starting the pump. If these procedures are
followed, you will have years of trouble-free service.
1. Read these rules and instructions carefully. Failure to follow them could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing.
3. For maximum safety, this product should be connected to a grounded circuit, equipped with a ground fault
interrupter device.
4. Before installing this product, have the electrical circuit checked by an electrician to make sure it is
properly grounded.
5. Before installing or servicing the pump, BE CERTAIN the pump power source is disconnected.
6. Make sure the line voltage and frequency of the electrical current supply agree with the motor wiring.
If motor is dual voltage type, BE SURE it is wired correctly for your power supply.
7. Complete pump and piping system MUST be protected against below freezing temperature. Failure to do
so could cause severe damage and voids the Warranty.
8. Discharge pressure not to exceed 85 PSI - suction pressure to 36 PSI - with 49 PSI boost.
9. Do not run the pump dry. If it is, there will be damage to the pump seal, and pump components.
10. Do not operate the pump in a flammable and/or explosive atmosphere.
WARNING